KEW 3125A High Voltage Insulation Testers in Bangladesh

  • • Insulation Resistance up to 1TΩ
  • • Short-Circuit Current up to 1.5mA
  • • Wide Test Voltage from 250V to 5000V
  • • Diagnosis Function of PI and DAR
  • • Newly-designed alligator clip
  • • It comes with a tough hard case
  • • Filter function reduces noise interference for obtaining stable measurement
  • • Large display with Bar Graph indication and backlight
  • • Live voltage warning
  • • Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V

Insulation resistance

Rated voltage250V500V1000V2500V5000V
Accuracy0.0 – 100.0MΩ 0.0 – 99.9MΩ 
80 – 1000M Ω  
0.0 – 99.9MΩ 
80 – 999MΩ 
0.80 – 2.00G  Ω
 0.0 – 99.9MΩ 
 80 – 999MΩ 
 0.80 – 9.99GΩ 
 8.0 – 100.0GΩ
0.0 – 99.9MΩ 
80 – 999MΩ 
0.80 – 9.99GΩ 
8.0 – 99.9GΩ 
80 – 1000GΩ
±5%rdg±3dgt±5%rdg±3dgt±5%rdg±3dgt±5%rdg±3dgt±5%rdg±3dgt
±20%rdg
(100GΩ or more)
Short circuit current1.5mA
Output voltage
Accuracy±10%-10 – +20%0 – +20%
Monitor±10%rdg±20V

Voltage measurement

Measuring rangeAC: 30 – 600V (50/60Hz), DC: ±30 – ±600V
Accuracy±2%rdg±3dgt

General

Applicable standardsIEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2,
IEC 61010-031, IEC 61326-1, 2-2
Power sourceDC12V : LR14/R14 × 8pcs
Dimensions177 (L) × 226 (W) × 100 (D) mm
300 (L) × 315 (W) × 125 (D) mm (Hard case)
Weight3125A: 1.9kg approx. (including batteries)
4kg approx. (including accessories)
Included Accessories7165A (Line probe: 3m), 7264 (Earth cord: 3m), 7265 (Guard cord: 3m),
8019 (Hook type prod), 9180 (3025A Hard case), 9181 (3125A Hard case),
LR14 (Alkaline battery size C) × 8, Instruction manual
Optional Accessories7168A (Line probe with alligator clip: 3m),
7253 (Longer line probe with alligator clip: 15m),
8302 (Adaptor for recorder)